Schneider Electric 25 hp Advanced Motor Starter, Tesys U32 A
Schneider Electric Power Base - U-Line SeriesSchneider Electric power bases are one of two basic units that are required every when used in conjunction with a control unit. This type of power base is independent of the control voltage motor power, it also incorporates the braking function.Schneider Electric TeSys UrangeTeSysproduct nameTeSys Udevice short nameLUBproduct or component typeNon reversing power basedevice applicationMotor controlMotor protectionpoles description3Psuitability for isolationYes[Ue] rated operational voltage690 V AC for power circuitnetwork frequency40...60 Hz[Ith] conventional free air thermal current32 A[Ie] rated operational current32 A at = 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit65 ms closing with LUCM for control circuitmechanical durability15 Mcyclesmaximum operating rate3600 cyc/hproduct certificationsCEULCSACCCEACASEFAATEXMarinestandardsEN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix Nfixing modeClipped (DIN rail)Screw-fixed (plate)connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigidControl circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable endtightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mmControl circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9…2.5 N.m flat screwdriver 6 mmPower circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mmwidth45 mmheight154 mmdepth126 mmnet weight0.9 kgcompatibility codeLUBEnvironmentIP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)IP20 conforming to IEC 60947-1 (other faces)IP40 conforming to IEC 60947-1 (front panel outside connection zone)protective treatmentTH conforming to IEC 60068ambient air temperature for operation-25…60 °C with LUCM-25…70 °C with LUCA, LUCB, LUCC, LUCDambient air temperature for storage-40…85 °Cfire resistance960 °C parts supporting live components conforming to IEC 60695-2-12650 °C conforming to IEC 60695-2-12operating altitude2000 mshock resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-274 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4non-dissipating shock wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-21 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-22 kV common mode 48...220 V DC conforming to IEC 60947-6-2immunity to radioelectric fields10 V conforming to IEC 61000-4-6immunity to microbreaks3 ms for control circuitimmunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11Packing UnitsUnit Type of Package 1PCENumber of Units in Package 11Package 1 Weight848 gPackage 1 Height5.2 cmPackage 1 width14.5 cmPackage 1 Length17 cmUnit Type of Package 2S03Number of Units in Package 210Package 2 Weight8.921 kgPackage 2 Height30 cmPackage 2 width30 cmPackage 2 Length40 cmUnit Type of Package 3P06Number of Units in Package 380Package 3 Weight79.868 kgPackage 3 Height80 cmPackage 3 width80 cmPackage 3 Length60 cmOffer SustainabilitySustainable offer statusGreen Premium productREACh RegulationREACh DeclarationEU RoHS DirectiveCompliantEU RoHS DeclarationMercury freeYesRoHS exemption informationYesChina RoHS RegulationChina RoHS declaration Product out of China RoHS scope. Substance declaration for your informationEnvironmental DisclosureProduct Environmental ProfileCircularity ProfileEnd of Life InformationWEEEThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsPVC freeYes
RELAY TENSE MDK-03 MONO-PHASE FOR CONTROLLING PUMP MOTOR
Description:It is designed for the control of pumps and submersible motors in wells and other similar places and to protect them from negative situations that may result from running without water, high or low voltage and current.1A - 30AInternal current transformersInternal contactor High/low voltage protectionHigh/low current protection Waiting time in case of errorAuto-reset time and countdownDemurrage Multiplier and DurationUpper electrode wait time Continuation of last shift (start/end)Characteristic:Measured value: undervoltage, overvoltage, overcurrent, undercurrentApplication: for electric motor, for pumpMounting: on DIN railOther features: digitalTrip current: Min: 1 A, Max: 30 A
Phase Sequence Phase Failure Voltage Analogue Adjustable Protection Relay (With Neutral Wire)
General Voltage Controller Relays are designed to avoid the failures of network voltage for the devices which have sensitive working voltage.Usage and Working Principle Make the connections according to the diagram. Set the device according to the required electrical charge. When the power is on, if the voltages are same as adjusted, relay led switches on and relay pulls. In this cases contact out is(NO)3 pole. When the volage values are avnormal, relay releases and led is switched off after waiting till the setted time is up. In this case contact out is (NC)1. GK-04FN type voltage controller relay doesn't work if the phase sequence is incorrect.MaintenanceSwitch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaning.WarningsPlease use the device according to the manual. Don’t use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device.SpecificationsOperating Voltage(Un)....: 3 x 380V AC + Neutral Operating Frequency.......: 50/60 Hz. High Voltage (U>)...........: 400V - 460V Low Voltage (U
Phase relay with display ENERGICAL RDP1. 380V
Phase relay with display ENERGICAL RDP1. 380VDescription :The phase relay provides protection against phase faults:It signals high voltage, low voltage, lack of phase, asymmetry and phase inversionFurther information :Weight: 0.13kgDimensions: 9.5 × 7.5 × 4.3cmCurrent (A): 8Frequency (HZ): 50/60Voltage (V): 380.
Overload relay Tense TRM-25
Characteristics:Controlled / measured valueoverloadOther characteristicsdigitalTripping currentMax: 25 AMin: 0.1 ADigital thermal relays are designed to prevent and control damage to loads caused by high current.0.1A - 25A (adjustable overload value)50% Fixed current asymmetryAdjustable delay time in case of errorAdjustable operating mode (automatic, semi-automatic, manual)Internal current transformers
Digital Potentiometer (4-20mA) TENSE PTM-02
Digital Potentiometer (4-20mA) TENSE PTM-02Digital potentiometers are control devices that produce analog output between 0-10V or 4-20mA values according to the set value.Microprocessor basedAnalog output: 4-20mAMenu entry and analog output control via front keysAnalog output control via digital inputsAdjustable scale upper and lower levelAdjustable upper and lower limit for SETSeparate function selection for the front keys and digital inputs to control analog outputPassword protectionSECU setting for enable/disable SET adjust menu entryHigh accuracyEEPROM memory to store settingsEasy connection with plug-in connectors
Digital (Manual / Semi-Automatic / Automatic Reset) Electronic Overload Asymmetry Relay Thermal Relay TRM 25 150-260VAC
General This overload devices are designed to prevent the loads getting harm from over currents and ability of control at the same time.TRM-03, TRM-12 and TRM-25 are have internal current tansformers.Usage of Device and Working Principle Make the connection of the device according to the connection diagram. Energize the device after making the connections. The display shows the set values for 5 seconds when the devices is energized.When the device is energized, you can make a overload adjustment with the "A>" knob While the setting is being made, the set value is shown on the left display. You can set the delay time with the "t" knob. Wtrine the setting is being made, the set value is shown on the left display. When th device is energized, the relay is energised, the contact output goes to terminal 3 and "OUT" led is on If the currents is higher than the set high current (A>), the device is counts the delay time and ERR on. After the time has elapsed, the relay is de-energised, the contact output goes to terminal 1, and "OUT" led is goes out. Delay time (Start Current): After the relay is energized or reset, the device does not current control for 5 seconds. Allows to delay time. Asymmetry: If there is more than 50% difference between the highest and lowest current passing on the phases, the device will enter asymmetry fault within 2 seconds. (When the motor starts, if a phase loss occurs, the motor can be prevented from being damaged.) When the device enters the asymmetry error, the display group of the two phases causing the fault flashes and error LED is on. If the current is less than these values, the device does not control asymmetry. 0,1A for TRM-03, 1A for TRM-12 and 2A for TRM-25. The device must be manually "Reset" button or power off to exit asymmetric errors.Reset ModesNote: Press the SELECT button for 10 seconds to change the mode. The mode light will change.WarningsWarnings - Please use the device according to the manual. - Don't use the device in wet. - Include a switch and circuit breaker in the assembly. - Put the switch and circuit breaker nearby the device, operateycan reach easily. - Mark the switch and circuit breaker as releasing connection for device. - Maximum currents to be applied to the devices; 3A for TRM-03, 12A for TRM-12 and 25A for TRN If current is applied above these values, the device may make incorrect measurement or damage echnical .Maintenance Switch off the device and release from connections. Clean the connection point of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaningTechnical SpecificationsOperating Voltage....... : 150V-260VAC Operating Freq.............: 50/60Hz Operating Power...........:
AVR 800VA Voltage Stabilizer
AVR 800VA Voltage StabilizerModel : avr-800vainput voltage : 100/110/120/220/230/240 -35% , +20%(-55%,+20%option)output voltage : 100/110/120/220/230/240+-8%P.F : 0.6Short circuit protection : fuse breaker/breaker Efficiency : >98%temperature : 0C°~40C°humidity : 10%~90%communication : RS232/USB( option)dimension : (W*H*D) (mm) 125*155*256 packing dimension : 176*207*280
AVR 5000VA Voltage Stabilizer
AVR 5000VA Voltage StabilizerModel : avr-5000vainput voltage : 100/110/120/220/230/240 -35% , +20%(-55%,+20%option)output voltage : 100/110/120/220/230/240+-8%P.F : 0.6Short circuit protection : fuse breaker/breaker Efficiency : >98%temperature : 0C°~40C°humidity : 10%~90%communication : RS232/USB( option)dimension : (W*H*D) (mm) 220*220*350mm packing dimension : 267*300*388mm
AVR 3000VA Voltage Stabilizer
AVR 3000VA Voltage StabilizerModel : avr-3000vainput voltage : 100/110/120/220/230/240 -35% , +20%(-55%,+20%option)output voltage : 100/110/120/220/230/240+-8%P.F : 0.6Short circuit protection : fuse breaker/breaker Efficiency : >98%temperature : 0C°~40C°humidity : 10%~90%communication : RS232/USB( option)dimension : (W*H*D) (mm) 210*210*300 packing dimension : 262*273*343
AVR 1500VA Voltage Stabilizer
AVR 1500VA Voltage StabilizerModel : avr-1500vainput voltage : 100/110/120/220/230/240 -35% , +20%(-55%,+20%option)output voltage : 100/110/120/220/230/240+-8%P.F : 0.6Short circuit protection : fuse breaker/breaker Efficiency : >98%temperature : 0C°~40C°humidity : 10%~90%communication : RS232/USB( option)dimension : (W*H*D) (mm) 140*200*285 packing dimension : 192*252*310
ADJUSTABLE VOLTAGE AND CURRENT PROTECTOR THREE-PHASE PTDR 4M 16A (MACHINE)
Protected against phase faults, it signals high-low voltage, phase failure, asymmetry and inversion and monitors current asymmetry.1.over voltage protection: adjustable2.Under-voltage protection: adjustable3.overcurrent protection: adjustable4.asymmetric protection5.Phase protection6. Active time and adjustable reconnection time7. Voltage and current can be manually calibratedWeight 0.36 kgDimensions 9.5 × 9.5 × 7.8 cmCurrent (A) 16Frequency (HZ) 50/60Voltage (V) 380
3 Phase Din rail adjustable Under Over Voltage Protector Voltage Monitoring Sequence Protection Relay Tomzn TOMPD-8S
Features●Microprocessor technology provideshighly accurate and repeatable protection●Built-in LCD and keypad afford a precisediqital setting●Compact modular 43mm housing●Adjustable over-and undervoltage,phase unbalance threshold●Independent adjustable delay time forovervoltage, undervoltage phase unbalance●Adjustable reset method automatic resetor manual reset●1 NO&INC contacts●Failure recording with last 3 faultsProtective FunctionsI Applications●Phase Loss(Failure)●Pase Sequence(Reversal)●Phase Unbalance(Asymmetry)●Undervoltage●OvervoltageApplications●Pumps, Fans, Refrigeration Unit, Blowers, Motors, Compressors, Lifts, Elevators, Crane, Mining excavators and conveyorsRated voltage: 380V 50-60Hz, Operating range: 300-490VAC
Automatic Stripping Multi Tool Stripper Wire Cable RG6/59
Features:1. Stripes outer jackets of coaxial cables, suitable for RG-58/6/7/11 cables.2. With Three Blades.3. Fully Adjustable & Replaceable Blades.4. Simple operation: lock the tool over the cable, spin clockwise, then pull off the unwanted portion.5. Made of High Impact Material.6. Needs no batteries or electric.7. Ergonomic design, easy to operate. Specifications:Product size: 98x18x34mm,wire stripping diameter 8mm,weight: approx. 40g
Digital Multimeter Koban KMD-23
MultimeterDigitalKoban KMD-23Digital multimeter with measurement category CATII 500V, 2000 resolution accounts and backlit display.It performs AC/DC voltage measurements, DC current, resistance and temperature.It has diode and continuity test and transistor test.