FKV-12 phase sequence protection relay
3000 DA
(9)

DESCRIPTION:Phase failure relayCharacteristics:Phase protection relays are designed to protect three-phase loads from damage caused by mains voltage. - Asymmetry: ~40%Measured value: phase orderNetwork: three-phase, ACApplication: for electric motorMounting: on DIN rail380V trigger voltage

ERV-09 Tense Flash Timer
3300 DA
(9)

ERV-09 Tense Flash TimerFEATURES:Function: flashingMounting: DIN rail, for panel mountingOther features: adjustableVoltage: Max: 260V Min: 24V DESCRIPTION :Flasher relay :  Timing relays are designed for use in all areas requiring time-based control. - Operation: 1sec. - 100 hours (adjustable)- Wait: 1sec. - 100 hours (adjustableDatasheet PDF

Digital Electronic Overload Relay Motor Protector Thermal Overload Relay Samwha-Dsp EOCR-SSD120 Digital
6900 DA
(11)

Features■ Compact Design■ Overload / Phase Loss / Locked Rotor protection ■ Accurately display the working current (the highest current of L1 and L3) through the front panel LED display■ When trip occurs, the cause is displayed on the LED window■ Phase loss protection (3 seconds)■ Convenient application: Selective use of single-phase (1P) and three-phase (3P) by DIP switch.■ Optional contact output [fail-safe (N)/non-fail-safe (R)]: simplify the adjustment of the contact state■ Easy installation due to both Din Rail and Panel MountingUsed for- Low Voltage Induced Electromotor (600V Level) Protective Relay- Break-Down Watch Current Relay- Alternative Replacement for the Existing RelayProtetcionProtective Item Operating (Trip) TimeOver-Current = O-TIMEPhase Loss = 3 sec.Locked Rotor = After D-time(Operating current> 200% of set current)SetAfter the installation is complete the settings as follows.Set knob: D-TIME(Delay Time) Set two to three seconds longer than the motor starting time.Set knob: O-TIME(Over-current run time) Set less than the motor's endurance time with over-current.Set knob: Load(Rated Current) Set over 110% of the motor's rated current of under 120% of its operating currentTrip Cause IndicationConfiguration MenuSpecificationsCurrent Range............ : Type05) 0.5-6A Type30) 3-30A Type60) 5-60A TYpe120) 10-120A Type600) Use an external CT(secondary 5A)over 120A with 05 type.Operating Voltage(Un).: Type220) 180-260VAC Operating Frequency....: 50/60HzOperating Power...........:

Thermal protection relay TENSE KON-TER-50
15900 DA
(8)

Thermal protection relay TENSE KON-TER-50DESCRIPTION:Digital contactors and thermal relays are designed to prevent and control loads from being damaged by high current. Contactor and thermal relay are combined in one product to save time, inventory and cost. 25A - 50A (adjustable overload value)50% Fixed current asymmetryAdjustable delay time in case of errorInternal current transformersInternal contactorIndicates the number of contacts usedIndicates the total number of working hoursFEATURES:Measured value: thermalContact configuration: 3NC, 3NONetwork: three-phaseMounting: on DIN railOther features: digitalTrip current:Min: 25AMax: 50ADownload catalogue PDF

TENSE SMK-03F PHASE FAILURE WITH LIQUID LEVEL CONTROLER RELAY (3 phase)
5600 DA
(32)

Combining with measuring electrodeAuto-monitoring water supply and drainage system, it is suitable to check the level of any conductive liquid. imbalance phase protection, high and low voltage protection, phase sequence protection- Operating Voltage: 160-- 260V AC- Contact:  5A/250V AC (Resistive Load)- Voltage Range: 160V - 225V AC (fixed)- Asymmetry Rate: 20% (fixed)Mounting: Din rail or front panel mountingManuel pdf

TENSE PTM-01 Digital Potentiometer (0-10V)
7500 DA
(22)

TENSE PTM-01 Digital Potentiometer (0-10V)Digital potentiometers are control devices that produce analog output between 0-10V or 4-20mA values according to the set value.• Microprocessor based• Analog output: 0-10V• Menu entry and analog output control via front keys• Analog output control via digital inputs• Adjustable scale upper and lower level• Adjustable upper and lower limit for SET• Separate function selection for the front keys and digital inputs to control analog output• Password protection• SECU setting for enable/disable SET adjust menu entry• High accuracy• EEPROM memory to store settings• Easy connection with plug-in connectors

TENSE ERV-YU Star/Delta Start Timer
3500 DA
(18)

TENSE ERV-YU Star/Delta Start TimerStar-delta time relays are designed to be used for the first start-up of three-phase motors. When the coil is energized, it switches to a star connection to enable the motor to start. The star stays connected for the set time and then goes into standby. When the waiting time is over, it allows switching to delta connection. Thus, it provides efficiency by reducing the current drawn by motors using large power during start-up.Characteristics:Travel: 0.1 sec. - 30 seconds. (Ajustable)Attendance: 15 ms. (Fixé)Function Tension (Un): 150 V-260 V VCA, 24 VCA/CCFrequency of function: 50/60 HzPuissance of function: < 4 VA- Y: 0,1 s - 30 s- Y-Δ: 10 ms - 500 ms-Affiliate screen: LED- Montage: Assemble on the railwayCatalogue PDF

TENSE ERV-08 digital time relay from 0.1sec – 100 hours (Adjustable)
3600 DA
(23)

TENSE ERV-08 digital time relay from 0.1sec – 100 hours (Adjustable)DESCRIPTION:Timing relays are designed for use in all areas requiring time-based control.0.1sec. - 100 hours. (Adjustable)VFEATURES:Technology: digitalFunction: multifunctionMounting: on DIN railProduct applications: for industryOther features: adjustableVoltage: Min: 12V Max: 240Download PDF

TENSE ERS-07 Right-Left Timer (Inverser)
4200 DA
(10)

TENSE ERS-07 Right-Left Timer (Inverser)DESCRIPTION:Time relays are designed for use in all areas requiring time dependent control. Operation: 1sec. - 100min. (adjustable)Wait: 1sec. - 100min. (adjustable)CHARACTERISTIC:Function: multifunctionMounting: DIN rail, for panel mountingProduct applications: for DIN railOther features: adjustable

Submersible Pump Control Relay Tense TDK-02
21600 DA
(19)

Spécifications : Ability to adjust high or low cosine setAbility to adjust high or low voltage and asymmetric voltageAbility to adjust high or low current Ability to adjust the upper electrode waiting timeEasy-to-use menuExtends the life of electrodesStart / Stop memoryInforms the motor maintenance timeManual automatic and semi-automatic resettingAbility to adjust liquid sensitivityAbility to store the error records- Operating voltage: 260- 470V AC- High voltage setting: 390V-500V- Low voltage setting: 260V-370V- High and low current setting: 2A - 300A - Contact:  5A/250V AC (resistive load)- Mounting: Front panel mounting PDF MANUEL

Submersible Pump Control Relay Tense TDK-01
19800 DA
(10)

 It is designed for the control of submersible pumps and motors in wells and similar places and to protect them from negative situations that may arise from waterless operation, high or low voltage and current.1A - 120AEasy Installation and Operation with 4x20 Graphic LCD DisplayWithout NeutralAbility to Work without ElectrodeHigh and Low Cosine SetHigh/Low Voltage ProtectionHigh/Low Current ProtectionVoltage Asymmetry ProtectionUpper Electrode Waiting TimeLiquid Sensitivity AdjustableKeeps Error RecordsStar-Delta Contact OutputFlasher ModeContinuation from the Last Working Position (Start/Stop)Report Engine Maintenance TimeManual, Semi-Automatic and Automatic Reset ModeExternal Start Stop Input2 Adjustable Alarm Outputs50Hz and 60Hz Operating Frequency SelectionDownlaod PDF

Schneider Electric 25 hp Advanced Motor Starter, Tesys U32 A
20000 DA
(3)

Schneider Electric Power Base - U-Line SeriesSchneider Electric power bases are one of two basic units that are required every when used in conjunction with a control unit. This type of power base is independent of the control voltage motor power, it also incorporates the braking function.Schneider Electric TeSys UrangeTeSysproduct nameTeSys Udevice short nameLUBproduct or component typeNon reversing power basedevice applicationMotor controlMotor protectionpoles description3Psuitability for isolationYes[Ue] rated operational voltage690 V AC for power circuitnetwork frequency40...60 Hz[Ith] conventional free air thermal current32 A[Ie] rated operational current32 A at = 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit65 ms closing with LUCM for control circuitmechanical durability15 Mcyclesmaximum operating rate3600 cyc/hproduct certificationsCEULCSACCCEACASEFAATEXMarinestandardsEN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix Nfixing modeClipped (DIN rail)Screw-fixed (plate)connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigidControl circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable endtightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mmControl circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9…2.5 N.m flat screwdriver 6 mmPower circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mmwidth45 mmheight154 mmdepth126 mmnet weight0.9 kgcompatibility codeLUBEnvironmentIP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)IP20 conforming to IEC 60947-1 (other faces)IP40 conforming to IEC 60947-1 (front panel outside connection zone)protective treatmentTH conforming to IEC 60068ambient air temperature for operation-25…60 °C with LUCM-25…70 °C with LUCA, LUCB, LUCC, LUCDambient air temperature for storage-40…85 °Cfire resistance960 °C parts supporting live components conforming to IEC 60695-2-12650 °C conforming to IEC 60695-2-12operating altitude2000 mshock resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-274 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4non-dissipating shock wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-21 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-22 kV common mode 48...220 V DC conforming to IEC 60947-6-2immunity to radioelectric fields10 V conforming to IEC 61000-4-6immunity to microbreaks3 ms for control circuitimmunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11Packing UnitsUnit Type of Package 1PCENumber of Units in Package 11Package 1 Weight848 gPackage 1 Height5.2 cmPackage 1 width14.5 cmPackage 1 Length17 cmUnit Type of Package 2S03Number of Units in Package 210Package 2 Weight8.921 kgPackage 2 Height30 cmPackage 2 width30 cmPackage 2 Length40 cmUnit Type of Package 3P06Number of Units in Package 380Package 3 Weight79.868 kgPackage 3 Height80 cmPackage 3 width80 cmPackage 3 Length60 cmOffer SustainabilitySustainable offer statusGreen Premium productREACh RegulationREACh DeclarationEU RoHS DirectiveCompliantEU RoHS DeclarationMercury freeYesRoHS exemption informationYesChina RoHS RegulationChina RoHS declaration Product out of China RoHS scope. Substance declaration for your informationEnvironmental DisclosureProduct Environmental ProfileCircularity ProfileEnd of Life InformationWEEEThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsPVC freeYes

RELAY TENSE MDK-03 MONO-PHASE FOR CONTROLLING PUMP MOTOR
9750 DA
(29)

Description:It is designed for the control of pumps and submersible motors in wells and other similar places and to protect them from negative situations that may result from running without water, high or low voltage and current.1A - 30AInternal current transformersInternal contactor High/low voltage protectionHigh/low current protection Waiting time in case of errorAuto-reset time and countdownDemurrage Multiplier and DurationUpper electrode wait time Continuation of last shift (start/end)Characteristic:Measured value: undervoltage, overvoltage, overcurrent, undercurrentApplication: for electric motor, for pumpMounting: on DIN railOther features: digitalTrip current: Min: 1 A, Max: 30 A

Phase Sequence Phase Failure Voltage Analogue Adjustable Protection Relay (With Neutral Wire)
3300 DA
(29)

General Voltage Controller Relays are designed to avoid the failures of network voltage for the devices which have sensitive working voltage.Usage and Working Principle Make the connections according to the diagram. Set the device according to the required electrical charge. When the power is on, if the voltages are same as adjusted, relay led switches on and relay pulls. In this cases contact out is(NO)3 pole. When the volage values are avnormal, relay releases and led is switched off after waiting till the setted time is up. In this case contact out is (NC)1. GK-04FN type voltage controller relay doesn't work if the phase sequence is incorrect.MaintenanceSwitch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaning.WarningsPlease use the device according to the manual. Don’t use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device.SpecificationsOperating Voltage(Un)....: 3 x 380V AC + Neutral Operating Frequency.......: 50/60 Hz. High Voltage (U>)...........: 400V - 460V Low Voltage (U

Phase relay with display ENERGICAL RDP1. 380V
3900 DA
(19)

Phase relay with display ENERGICAL RDP1. 380VDescription :The phase relay provides protection against phase faults:It signals high voltage, low voltage, lack of phase, asymmetry and phase inversionFurther information :Weight: 0.13kgDimensions: 9.5 × 7.5 × 4.3cmCurrent (A): 8Frequency (HZ): 50/60Voltage (V): 380.