Schneider Electric 25 hp Advanced Motor Starter, Tesys U32 A

20000 DA
(26)

Schneider Electric Power Base - U-Line SeriesSchneider Electric power bases are one of two basic units that are required every when used in conjunction with a control unit. This type of power base is...
Read Full Description

  • 1 Year Warranty
  • 30 Day Return
  • Cash on Delivery available


Share:

Schneider Electric Power Base - U-Line Series

Schneider Electric power bases are one of two basic units that are required every when used in conjunction with a control unit. This type of power base is independent of the control voltage motor power, it also incorporates the braking function.

Schneider Electric TeSys UrangeTeSysproduct nameTeSys Udevice short nameLUBproduct or component typeNon reversing power basedevice applicationMotor controlMotor protectionpoles description3Psuitability for isolationYes[Ue] rated operational voltage690 V AC for power circuitnetwork frequency40...60 Hz[Ith] conventional free air thermal current32 A[Ie] rated operational current32 A at <= 440 V23 A at 500 V21 A at 690 Vutilisation categoryAC-44AC-43AC-41[Ics] rated service breaking capacity50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 Vauxiliary contact composition1 NO + 1 NCauxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1type mirror contact (1 NC) conforming to IEC 60947-1[Uc] control circuit voltage24 V AC 50/60 Hz24 V DC48...72 V AC 50/60 Hz48...72 V DC110...240 V AC 50/60 Hz110...220 V DCComplementarytypical current consumption200 mA at 24 V DC I maximum while closing with LUCM220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD75 mA at 24 V DC I rms sealed with LUCM80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCDheat dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD1.8 W for control circuit with LUCMsafety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit65 ms closing with LUCM for control circuitmechanical durability15 Mcyclesmaximum operating rate3600 cyc/hproduct certificationsCEULCSACCCEACASEFAATEXMarinestandardsEN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix Nfixing modeClipped (DIN rail)Screw-fixed (plate)connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigidControl circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable endtightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mmControl circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9…2.5 N.m flat screwdriver 6 mmPower circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mmwidth45 mmheight154 mmdepth126 mmnet weight0.9 kgcompatibility codeLUBEnvironmentIP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)IP20 conforming to IEC 60947-1 (other faces)IP40 conforming to IEC 60947-1 (front panel outside connection zone)protective treatmentTH conforming to IEC 60068ambient air temperature for operation-25…60 °C with LUCM-25…70 °C with LUCA, LUCB, LUCC, LUCDambient air temperature for storage-40…85 °Cfire resistance960 °C parts supporting live components conforming to IEC 60695-2-12650 °C conforming to IEC 60695-2-12operating altitude2000 mshock resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-274 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4non-dissipating shock wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-21 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-22 kV common mode 48...220 V DC conforming to IEC 60947-6-2immunity to radioelectric fields10 V conforming to IEC 61000-4-6immunity to microbreaks3 ms for control circuitimmunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11Packing UnitsUnit Type of Package 1PCENumber of Units in Package 11Package 1 Weight848 gPackage 1 Height5.2 cmPackage 1 width14.5 cmPackage 1 Length17 cmUnit Type of Package 2S03Number of Units in Package 210Package 2 Weight8.921 kgPackage 2 Height30 cmPackage 2 width30 cmPackage 2 Length40 cmUnit Type of Package 3P06Number of Units in Package 380Package 3 Weight79.868 kgPackage 3 Height80 cmPackage 3 width80 cmPackage 3 Length60 cmOffer SustainabilitySustainable offer statusGreen Premium productREACh RegulationREACh DeclarationEU RoHS DirectiveCompliantEU RoHS DeclarationMercury freeYesRoHS exemption informationYesChina RoHS RegulationChina RoHS declaration Product out of China RoHS scope. Substance declaration for your informationEnvironmental DisclosureProduct Environmental ProfileCircularity ProfileEnd of Life InformationWEEEThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsPVC freeYes

0 Review For Schneider Electric 25 hp Advanced Motor Starter, Tesys U32 A
Add a review

Releted Products

Subscribe Our Newsletter

Update cookies preferences